Skip to content
DE EN

Changelog

2026-04-16

Version 2.21.0 brings a complete run data export: measurement data can be downloaded as CSV via configurable runs. A new Gateway reconnect mechanism additionally enables manual restoration of connections directly from the user interface.


  • Run Export — Runs can be downloaded as a CSV file. The interface shows all completed runs and provides direct download access to the exported data.
  • Run Configuration — Runs can be created and configured via the interface. Supported trigger types: alarm trigger (with pre and post time), external trigger (start & stop), time trigger (start & stop), and interval trigger. Existing configurations can be activated and deactivated.
  • Variable Path in Run Configuration — Run variables now support an additional parameter for the full group path to the variable (e.g. Device3/Group2/Variable12).
  • Gateway Endpoint Reconnect — When connection problems occur, the connection of a Gateway endpoint can be manually forced via the interface. The broker configuration is updated before the reconnect. Connection status and endpoint details are directly viewable.
  • Gateway Insights: Extended System Data — The system now transmits additional device information to the Hub: device ID, software version, MAC addresses, manufacturer, serial number, and the available storage space of the database partition.
  • Run without Variables — A run without defined process variables caused an error during CSV export. The run is now no longer activated if no variables are stored.
  • Email Notifications for Alarms — Email notifications for Grafana alarms could no longer be sent after version 2.18, as the underlying system service was no longer available. The device name is now correctly retrieved via the new OS service.
  • Run Interval Initialisation — Interval-type runs were not correctly initialised when created: the start time was not set and the first data record was skipped.

GroupComponentVersionNotes
Web UIAdvanced4.10.13
AppBatching1.0.0New
CoreNotification Hub1.1.0
GatewayEndpoint AWS1.5.2
GatewayDispatcher Insights1.11.7
SystemProxy1.20-2.21
HostDocker Config1.0.2
  • Restart required — This update automatically triggers a device restart. When updating from version 2.20, the system also validates that the required DEB Crawler Packs are installed.

2026-03-03

Note: System restart required This update requires a system restart. The restart can be performed at any time, but must occur before a further update is applied.

The update includes a pre-installation validation of the installed packages (prerequisite: version 2.19). If the validation fails, the update process is aborted — no changes are made.


Version 2.20.0 introduces the OPC UA connector: connection to OPC-UA-capable devices with secured connection, variable explorer, and status display. Several bug fixes in the OPC and Gateway areas improve stability.


  • OPC UA Connector — Connection to OPC-UA-capable devices is now possible. The connector supports gradual exploration of the device variable tree (no pre-loading of the full structure), secured connections with password authentication, and all common data and access types (Bool, String, DateTime, Array, etc.).
  • OPC Quick Insights — Connection status, error messages, and warnings from the OPC connector are displayed in the Quick Insights view, analogous to the Simatic connector.
  • OPC Performance Test — The performance test button for the OPC connector is now active and delivers valid test results.
  • Device ID (Crawler ID) — Each device receives a unique UUID, which is provided via the system info route. This ID enables reliable assignment of the device in Hub and Companion.
  • Updater: Subversions — Update bundles can now set a subversion without incrementing the main version. This enables individual components or special features to be retrofitted.
  • OPC: Password Change on Device — A password change on the OPC device was ignored after the first time and only took effect after a container restart. The cause was a faulty deduplication of configuration messages.
  • OPC: Reconfiguration of Variables — Changes to variables (e.g. interval, activation) were not applied by the connector. Configuration events are now processed correctly.
  • OPC: Incorrect Performance Test Result — The performance test did not return a valid result when the sampling rate could not be achieved. The result is now correctly reported as failed.
  • OPC Quick Insights: Unclear Messages — Status messages for connection and password issues were partially unclear. The messages have been revised and aligned with the format of the Simatic connector.
  • Gateway: Send Switch Required Restart — The switch in the MX Dispatcher area for controlling the send process only took effect after a device restart. The change is now applied immediately.

ComponentVersionNotes
OS Image
Web UI Advanced4.9.20
Web UI API1.24.1
Source Control (SourceConfig)1.3.1
Gateway Manager1.10.0
Host Updater2.4.0
Host Proxy1.20-20260217
Source OPC1.7.2
  • Upgrade from v2.19 only supported. Ensure v2.19 is fully installed before applying this update.

2026-01-30

Note: Automatic restart This update automatically restarts the device immediately, as the new updater is required for the second installation step.

The update includes a pre-installation validation of the installed packages (prerequisite: version 2.18). If the validation fails, the update process is aborted — no changes are made.


Version 2.19.0 brings extensive improvements to the Simatic connector: faster connection establishment, gradual exploration without pre-loading the full structure, and optimised RAM usage. The user interface has been extended with status-dependent controls and a clearer variable structure.


  • Simatic: Gradual Exploration — The variable structure of a Simatic device is now loaded incrementally, without downloading the full structure upfront. This prevents crashes with large program structures and significantly reduces RAM usage.
  • Simatic: Direct Data Block Addressing — Data blocks are now directly accessible without overlaid group levels.
  • UI: Variable Structure — Arrays are explicitly labelled as arrays in the variable explorer (displaying the array size). Data blocks and group structures are sorted alphanumerically.
  • UI: Status-dependent Control Lock — The performance test and import-from-device functions are locked while no connection to the device is established.
  • Configuration Migration — A separate update package is available for devices with an existing variable configuration, which migrates the configuration to the new Simatic format. Note: after the migration, Grafana dashboards must be reconfigured.
  • Updater: Script Execution — The update system now supports pre- and post-installation scripts that are executed as part of an update bundle.
  • Simatic: Slow Connection Establishment — Connection establishment to the PLC could take up to 5 minutes on some devices. Connection handling and status display have been completely redesigned.
  • Simatic: Performance Test Returned Invalid Results — The performance test did not return valid results when the sampling rate could not be achieved. Results and code structure have been revised.
  • Simatic: Password Protection Always Active on Creation — When creating a new Simatic device, password protection was always pre-selected, even when no password was entered.
  • Simatic: Disabled Exclude List Ignored Variables — A disabled exclude list caused temporarily unavailable variables to be permanently ignored. The exclude list is now always active and configurable via parameters.
  • Simatic: Health Status with Wrong Password — After a password change with an incorrect password, the health status was not correctly set to “Unhealthy”. Only a restart of the connector restored the correct state.
  • NTP: Service Inactive after Restart — The NTP service switched off after a system restart.

ComponentVersionNotes
OS Image
Web UI Advanced4.9.17
Source Control (SourceConfig)1.3.0
Host DateTime1.3.2
Host Updater2.2.1
Host Dockerenvironment1.0.1
Source Simatic4.4.2
APP Redprocessor0.1.0newly registered
APP Redprocessor Browser1.0newly registered
Source Modbus3.5.1newly registered
Core Gateway Manager1.9.7newly registered
Core Auth1.1.1newly registered
Core Database Management1.2.6newly registered
Core Grafana Connector1.3.2newly registered
Core Notification Hub1.0.21newly registered
Core Source Info1.0.0newly registered
Core Struct Import CSV1.2.2newly registered
Core Struct Registry1.11.0newly registered
Core Struct Templates1.0.5newly registered
  • Upgrade from v2.18 only supported.
  • After applying the optional config migration package, Grafana dashboards must be reconfigured.

2025-12-05

Critical Patch — Updater Depending on the hardware in use, larger update packages could not be fully uploaded. The upload was aborted with a timeout.


Version 2.18.2 fixes an issue where the upload of larger update packages timed out depending on the hardware. A full fix of the underlying issue in the API service will follow in version 2.19.


  • Updater: Upload of larger packages failed — Depending on the hardware configuration, the high system load during the upload caused the process to abort with a timeout, and the update package was not fully transferred. The upload is now forwarded directly to the updater service.

ComponentVersionNotes
System Proxynew nginx config

None.


2025-11-08

Critical Patch — Gateway Without this patch, the Gateway service could not retrieve the device’s hostname, which is required to authenticate with the cloud. The Gateway function was therefore completely out of service.


Version 2.18.1 is a critical patch that restores the Gateway connection to the cloud.


  • Gateway: Connection to cloud interrupted — After the infrastructure overhaul in version 2.18, the Gateway service could no longer retrieve the device’s hostname. The Gateway connection to the cloud was therefore completely interrupted.

ComponentVersionNotes
System Proxynew nginx config

None.


2025-10-09

Note: Two restarts required This update requires two consecutive restarts, as OS components and the Linux kernel are also being updated.

The update includes a pre-installation validation of the installed packages (prerequisite: version 2.17) as well as a check of the available storage space. If either check fails, the update process is aborted — no changes are made.


Version 2.18.0 brings a completely redesigned update interface and a new Docker infrastructure that enables direct updates of individual components. Network configuration and discovery have been extended for the Companion app. Several stability issues in the Simatic connector have been resolved.


  • Updater: New Interface — The updater features a completely redesigned user interface with an update history and a dedicated process page. Available storage space is checked before the update.
  • Setup Wizard: Input Validation — Invalid inputs are caught and reported immediately during the setup process.
  • Network Configuration (Initial Setup) — Network interfaces can be configured via the initial setup.
  • Discovery: Extended Device Information — The Discovery service displays additional fields for discovered devices.
  • Firmware Update via Companion — The foundation for firmware update functionality via the Companion app has been implemented.
  • Simatic: High Memory Load — The Simatic connector caused uncontrolled memory consumption under certain conditions. The fix from patch 2.17.1 has been incorporated into this version.
  • Simatic: Exclude List Ignored Variables — A faulty exclude list implementation caused variables to be incorrectly ignored.
  • Simatic: NaN Error in Quick Insights — When querying the device ID, a NaN error occurred that caused incorrect displays in Quick Insights.
  • IO Load Problem — A problem with elevated IO load that had existed since version 2.16 was resolved by adjusting the Influx configuration.
  • CSV Config Import: Invalid Characters — Invalid characters in the address field are now caught during CSV import.

ComponentVersionNotes
OS Image
Web UI Advanced4.9.8
Web UI API1.20.0
Web UI Basic2.2.1
Web UI Configuration1.0.3
Core CSV-Config-Import1.2.2
Core Kapacitor1.5.3-udf
Core Watchdog0.1.3
Host Docker Environment1.0.0
Host Discovery2.0.6
Host Network API2.6.5
Host OS Info1.0.4
Host Secure Pack2025.1
Host Updater2.1.2
Source Simatic4.3.2
System Grafana7.4.5
System Influx1.8
System Postgres11.4
System Proxy1.20
System Worker Insights1.20.4
System Worker Measurements1.20.4
APP Docu1.0.0new Compose config only
System Broker3.8.0new Compose config only
  • Upgrade from v2.17 only supported.
  • Docker infrastructure overhaul: all services migrated to new Docker Compose structure. Direct per-container updates are now possible.

2025-08-28

[!CAUTION] Critical Patch — Simatic Connector This patch should be applied to all crawlers promptly. The bug can lead to a complete failure of the crawler, as the Simatic service consumes the memory available to other applications.

During the connection establishment to the PLC, the Simatic service was consuming an excessive amount of memory. As a result, other services no longer had sufficient memory available, which could lead to a total failure of the crawler.

AreaChange
Source SimaticFixed memory leak during connection establishment to PLC
GroupComponentVersion
SourceSimatic4.3.2

2025-03-17

Note: System restart required This update requires a system restart because duplicates in the core Compose configuration are cleaned up. During the restart, all affected containers will be recreated.


Version 2.17.0 brings extensive enhancements to the Simatic connector: live view, quick preview, password protection, and Quick Insights. The Modbus connector has been extended with IP address change and endianness configuration. The user interface has been updated with a revised navigation menu and improved connection status display.


  • Simatic: Live View — The most recent measured value of a variable is displayed directly in the variable browser.
  • Simatic: Quick Preview — Fast time-series preview of a variable’s value as a chart, accessible directly from the browser.
  • Simatic: Password-protected Devices — Connections to password-protected Simatic devices are supported.
  • Simatic: Quick Insights — Dynamic connection status and log messages are displayed directly from the Simatic service.
  • Simatic: Improved Timeout Behaviour — The connection timeout behaviour on connection drops has been revised.
  • Modbus: Change IP Address — The IP address of a Modbus device can be changed afterwards without having to recreate the device.
  • Modbus: Configurable Endianness — Big-endian and little-endian are configurable at the device and variable level.
  • UI: Restart Source Extensions from UI — Simatic and Modbus containers can be restarted directly from the interface.
  • UI: Navigation Menu — The navigation menu has been revised and improved.
  • WebUI does not start after device restart — The user interface did not start correctly after a restart of the crawler.
  • Error during Initial Setup — An error occurred when setting up the device for the first time.
  • Gateway Manager: Configuration Delivery — The configuration was not correctly delivered to the Gateway Dispatcher (affects only installations with the Gateway function enabled).

ComponentVersionNotes
OS Image
Web UI Advanced4.8.18
Web UI Basic2.2.0
Web UI API1.17.6
Core Source Control (SourceConfig)1.2.1
Core Source Info1.0.0new
Source Simatic4.2.3
Source Modbus3.5.1
Gateway Manager1.9.7

None.


2025-02-26

Critical Patch — Gateway After a system restart, no measurement data was being sent toward the cloud. The Gateway function was therefore completely out of service.


Version 2.16.1 is a critical patch that restores Gateway data transmission after a device restart.


  • Gateway: Data not sent after restart — After a system restart, continuous measurement values were no longer transmitted to the cloud. Structural data and insights were sent correctly; only the measurement data was missing. The issue could only be worked around by manually changing a variable on the Gateway.

ComponentVersionNotes
Gateway Manager1.9.6

None.


2025-02-06

Note: Database restarts — brief data loss possible This update restarts the databases. A brief period of data loss will occur as a result. This is technically necessary due to the included database migrations.

Note: This update includes the changes from patch 2.15.1 and can be applied directly on top of version 2.15.0.


Version 2.16.0 introduces controlled transmission of measurement data via the Gateway trigger. IO load problems from earlier versions have been permanently resolved.


  • Gateway: Controlled Dispatching (Conditional Dispatching) — When the Gateway is enabled, variables can be selectively sent to the cloud via a source trigger instead of transmitting continuously.
  • Variables: Cascading Deletion — When a device or group is deleted, the associated variables are automatically deleted along with it.
  • IO Load Problem — An excessive IO load that had been known since earlier versions was permanently resolved by adjusting the InfluxDB configuration and introducing resource limits.

ComponentVersionNotes
OS Image
Web UI Advanced4.7.2
Web UI API1.16.8
Gateway Manager1.9.4
  • Upgrade from v2.15 or later supported (2.15.1 changes included).
  • Database migrations are applied during update — brief data loss possible.

26 November 2024

[!NOTE] This patch is bundled with Version 2.16.0 and can therefore be applied directly on top of Version 2.15.0.

AreaDescription
Device ManagementError when reaching the maximum number of devices resolved
PLC CreationCreating PLCs with the same IP address corrected
Variable BrowserIndividual variables can again be correctly deleted
AreaDescription
Character EncodingUTF-8 support for files exported from Excel
Special CharactersError with special character ”…” (ellipsis) resolved
AreaDescription
StabilityGeneral stability improvements
ReconnectReconnection to the PLC corrected
ExcludeListWhen using absolute addressing, disabling the ExcludeList was not possible — resolved
GroupComponentVersion
Web UIAdvanced4.5.17
CoreCSV Parser1.2.1

9 October 2024

  • Target/actual comparison of sampling rate: the measured sampling rate of the PLC is compared against the configured rate to ensure no data is missed or distorted
  • When importing measured variables, groups and variables are now loaded partially — improved performance with large data structures
  • Crawler documentation in PDF format available directly in the Web UI (Advanced and Basic UI)
  • New page showing all devices with their current connection status
ImprovementDescription
Excel CompatibilityCSV files from Excel are supported (automatic conversion to UTF-8)
Group StructuresImporting group structures via path specification (any hierarchy depth)
Duplicate DetectionDuplicate addresses within a group are detected and reported
Optional ColumnsColumn “Crawler Data Type” is optional; column “isActive” can be empty (default: true)
Error MessagesImproved error messages for invalid CSV files (e.g. empty file)
AreaChange
NotificationsReduced number of duplicate notifications
  • General functional improvements
GroupComponentVersion
Web UIAdvanced4.5.13
Web UIBasic2.1.6
Web UIAPI1.16.7
CoreCSV Parser1.1.8
SourceSimatic4.0.2

The update bundle supports migration from Version 2.14 to 2.15. Ensure that Version 2.14 is fully installed before applying the update.


28 August 2024

[!WARNING] Restart Required After the update, the Crawler must be restarted; otherwise the changes will not take effect.

[!NOTE] This patch includes all changes from Version 2.14.3 and fully supersedes it.

This patch consolidates the stability measures from 2.14.3 and supplements them with a new Simatic version that combines all features from Version 2.13 and 2.14.0, as well as the capability for partial exploration.

AreaChange
Core DumpsDisabled in system services and connectors
Log FilesSize limited to max. 10 MB, max. 3 files per service
Host ServiceExisting log data is cleaned up during the update
Source SimaticUpdate to Version 4.0.1 — revised service with partial exploration and Arcon abstraction
GroupComponentVersion
CoreSource Control (SourceConfig)1.1.2
SourceSimatic4.0.1

1 August 2024

[!WARNING] Restart Required After the update, the Crawler must be restarted; otherwise the changes will not take effect.

This patch improves overall system stability by disabling core dumps and limiting log file sizes. Both measures reduce uncontrolled memory consumption during operation.

AreaChange
Core DumpsDisabled in system services and connectors
Log FilesSize limited to max. 10 MB, max. 3 files per service
Host ServiceExisting log data is cleaned up during the update
GroupComponentVersion
CoreSource Control (SourceConfig)1.1.2

7 July 2024

This patch restores support for newer Simatic controllers configured with TIA Portal V18 or later. The connection initialisation has been corrected.

AreaChange
Source SimaticUpdate to Version 3.5.6
TIA V18+Support for controllers from TIA Portal V18 onwards restored
Init StringMinimum length of the init string is handled correctly when it has not been set
Accon LibLibrary for controller communication updated
GroupComponentVersion
SourceSimatic3.5.6

23 June 2024

[!WARNING] Limited Simatic Compatibility This version does not support Simatic controllers configured with TIA Portal V18 or later. For TIA V18+, please update to Version 2.14.2.

The Simatic service from Version 2.14.0 exhibited stability issues. This version includes a downgrade to the last known stable Simatic version (3.5.4). As a result of the downgrade, certain features are temporarily unavailable.

AreaChange
Source SimaticDowngrade to Version 3.5.4 (last stable version)
IP AddressChanging the device IP is not possible (temporarily disabled)
ExcludeListDisabling the ExcludeList is not possible (temporarily disabled)
GroupComponentVersion
SourceSimatic3.5.4

13 March 2024

[!CAUTION] Not Recommended — Known Stability Issues This version contains known stability issues with the Simatic Connector. It is recommended to update directly to Version 2.14.4.

[!WARNING] Restart Required This update requires a system restart, as configuration changes only take effect after a restart.

FeatureDescription
Bulk EditingMeasured variables in the Gateway can be edited and deleted in bulk
Meta-Info ImportMeasured variables can be imported via meta-information from device measured variables
Multiple DispatchersSupport for multiple dispatchers per endpoint (e.g. periodic + ad-hoc dispatch)
Structure DispatcherNew dispatcher: transfers Crawler device and measured variable structures (bookable)
Ad-Hoc DispatcherNew dispatcher: high-resolution data points for individual measured variables within a limited time range (bookable)
Aggregation IntervalsIntervals 1s and 5s have been removed (excessive system load)
AreaChange
NavigationNavigation to the NuP Dispatcher directly via the Advanced UI
LayoutGeneral layout improvements
Setup WizardBugfix: display error for network adapter resolved
AreaChange
AWS EndpointAdjusted endpoint for improved stability of connection establishment
Origin IDIntroduced to support multiple simultaneous dispatchers
MXS / MXHSeparate update packages for MXS and MXH (in addition to the standard update)
GroupComponentVersion
Web UIAdvanced4.0.26
Web UIAPI1.16.3
GatewayManager1.8.8
Gateway (MXS, MXH)Dispatcher MX2.6.0
Gateway (MXS, MXH)Structure Dispatcher1.2.0 (new)
Gateway (MXH)Ad-Hoc Dispatcher1.1.1 (new)
Gateway (MXS, MXH)AWS Endpoint1.3.0

The update bundle supports migration from Version 2.13 to 2.14. Ensure that Version 2.13 is fully installed before applying the update.


15 January 2024

[!CAUTION] Not Recommended — Known Stability Issues This version contains known stability issues with the Simatic Connector. It is recommended to update directly to Version 2.14.4.

  • Measured variables can be imported via CSV file for all device types
  • Email dispatch for Grafana alarms (new service)
AreaChange
Device FavouritesNotice displayed when the maximum number of favourites is reached
AppearanceRevised design of the Web UI
AreaChange
ExcludeListComplete overhaul (previously: BlackList) — improved functionality
ExcludeListCan be disabled in the UI
IP AddressIP address of a device can be changed (connection is rebuilt automatically)
ComponentDescription
StructServiceDuring a factory reset, variables in the StructDB were not completely deleted

To prevent cascading issues with a large number of measuring devices, queue lengths have been limited for all workers:

Workerprefetch_count
system.worker.insights.log1000
system.worker.insights.endpoint100
system.worker.insights.source50
system.worker.measurement100
system.worker.measurement.metric100
GroupComponentVersion
Web UIAdvanced4.0.19
Web UIBasic2.0.0
Web UIAPI1.15.2
CoreNotification Hub1.0.21 (new)
CoreCSV Parser1.0.7 (new)
SourceSimatic3.9.5

The update bundle supports migration from Version 2.12.2 to 2.13. Ensure that Version 2.12.2 is fully installed before applying the update.


24 October 2023

When unknown symbolic data types were present on the PLC, log messages were generated at a high frequency, which could cause significant performance degradation depending on the system. Affected data types: S7_HW_SUBMODULE, S7_HW_ANY, S7_CONN_OUC, S7_Pointer, S7_Variant. These log entries have been disabled.

AreaDescription
Source SimaticHigh-frequency log messages for unknown PLC data types disabled
GroupComponentVersion
SourceSimatic3.5.4

No separate VM package required. The update bundle supports migration from Version 2.12.1 to 2.12.2.


18 September 2023

[!NOTE] Version 2.12.0 contained bugs when changing the IP address and during the Simatic Discovery timeout. It is recommended to skip Version 2.12.0 and update directly to 2.12.1. The update package supports installation based on either 2.11 or 2.12.

FeatureDescription
Array Data TypeSimatic now supports the Array data type
FeatureDescription
String Data TypeModbus now supports the String data type
AreaChange
FavouritesMax. 3 device favourites in the Advanced UI
Device LimitMax. 5 devices in the Advanced UI
Login DurationLogin validity extended to 1 hour
FirefoxLogin in Firefox browser is now possible
AreaChange
Insights DispatcherSend interval extended to 5 minutes (if configured)
Cloud Data LoadReduction of data load towards the cloud — measurement values prioritised over service information
AreaChange
ConnectorsLimitation of simultaneous connectors to guarantee performance
Auth ServiceDuring a reset, the configured password from the app settings is always used
Simatic DiscoveryTimeout increased to 60 seconds
GroupComponentVersion
Web UIAdvanced3.20.10
Web UIAPI1.14.6
Web UIAuth1.1.1
SourceSimatic3.5.3
SourceModbus3.3.3

The update bundle supports migration from Version 2.11 or 2.12.0 to 2.12.1. No separate VM package required.


September 2023

[!CAUTION] Not Recommended — Known Bugs This version contains bugs when changing the IP address of devices and when the Simatic Discovery times out. It is recommended to update directly to Version 2.12.1. The update package for 2.12.1 supports installation based on either 2.11 or 2.12.0.


30 May 2023

FeatureDescription
Interval SelectionWhen adding a measured variable, the desired aggregation interval is set directly
Interval ChangeThe interval can be changed after the fact
Available Intervals1s, 15s, 30s, 1m, 10m, 30m, 1h
Existing DataEntries already present retain their previous default value of 1 minute after the update

Variables with a 10-second interval are automatically changed to 60 seconds during the update.

FeatureDescription
Send BacklogCurrent mode, timestamp of the most recent and backlogged measurement point, and the last send time are displayed in the web frontend
Variable AddressAddress of the measured variables configured in the Gateway is displayed
  • Health checks available for Manager, Dispatcher, and Endpoint
  • All Gateway projects migrated to .NET 6.0
  • Improved logging levels and queue names
  • Manager: unnecessary Kapacitor tasks are deleted automatically
  • Manager: variable configuration changes propagate the full data set
  • API error messages use RFC7807 format
GroupComponentVersion
UIAdvanced UI3.18.4
UIWeb API1.14.3
GatewayManager1.7.8
GatewayDispatcher MX2.5.0
GatewayEndpoint AWS1.1.4

No separate VM package required. The update bundle supports migration from Version 2.10 to 2.11.


20 February 2023

FeatureDescription
Login for SettingsThe settings page requires a login (user: admin)
Password ManagementPassword is set during initial setup and can be changed at any time in the settings
Factory ResetPassword is also reset when performing a factory reset
FeatureDescription
Primary AdapterA primary network adapter must be defined for internet requests (routing)
Default AdapterOn delivery and after a factory reset, the X1 adapter is configured as the primary adapter
Discovery ToolNetwork settings via the DiscoveryTool always refer to the first adapter, regardless of the configured primary adapter
  • Docker infrastructure updated
  • Containerd configuration adjusted (fixes errors in Suspend Mode on VMs)
  • I/O load reduced through configuration adjustments
  • compose-up.sh is now included in the update package (previously, the local file was modified directly)
  • Health checks added for Web UI Advanced and Auth Service
GroupComponentVersion
Web UIAdvanced UI3.17.4
Web UIWeb API1.14.2
CoreAuth Service1.0.0 (new)

The update bundle supports migration from Version 2.9 to 2.10.


1 December 2022

FeatureDescription
Current Data PacketsAfter a connection drop, current data packets are sent regularly alongside historical data
FeatureDescription
Start PageWhen accessing the Crawler address, the user UI (Basic UI) opens first; the settings pages can be reached via a button
Connection StatusThe connection status of configured field devices is displayed on the device pages and device list; connection changes are shown as notifications
NotificationsImproved notifications and alerts
AreaDescription
Basic UINode Red can be called embedded in the Basic UI
GroupComponentVersion
Web UIAdvanced UI3.16.1
Web UIBasic UI1.2.3
GatewayDispatcher MX2.1.6

The update bundle supports migration from Version 2.8 to 2.9.


6 September 2022

FeatureDescription
OverviewDisplay of all Influx databases
Clear DatabaseIndividual databases can be cleared
Retention PoliciesRetention policies can be configured
Disk ForecastDisplay of current disk usage and rough forecast for when the disk will be full
FeatureDescription
Individual FilteringWatchdog with configurable filters for individual monitoring
UI IntegrationDevice connection status displayed directly in the Web UI
Gateway IntegrationWatchdog data is integrated into the Insights Dispatcher (Gateway)
  • Revised device pages and settings pages
  • New alerts and notifications on device pages
  • Renaming of “Variables” to Measured Variables throughout the UI
  • Network settings are only applied after confirming “Complete”
  • VariableBrowser: Navigation structure is preserved when changes are made to measured variables
  • Bugfix: Asynchronicity issue in the publisher library resolved
  • Bugfix: Measured variables that could not be retrieved from the PLC are now retried multiple times before being discarded
GroupComponentVersion
CoreDatabase Manager2.6.1
SourceSimatic3.4.7
Web UIAdvanced UI3.13.9
Web UIBasic UI1.1.0
Web UIWeb API1.0.13.7
CoreWatchdog0.1.3
GatewayDispatcher Insights1.10.0

The update bundle supports migration from Version 2.7.1 to 2.8.


2022-07-28

AreaChange
Remote-Controlled ConnectorsConnectors can be marked as “remote-controlled” and will then not be created, started, stopped, or deleted by the SourceConfig service
AreaChange
Group SelectionIn addition to “Device + Measurement Variable”, the group structure can now also be used for dashboard selection; existing dashboards remain compatible
AreaDescription
StructServiceIPCC events when deleting a measurement variable were not sent correctly in all cases
GroupComponentVersion
CoreStructService1.11.0
CoreSourceConfig1.0.2
CoreGrafana Connector1.3.1
CoreDevice Config Management1.0.5

The update bundle supports a migration from version 2.7 to 2.7.1.


2022-07-11

FeatureDescription
Field Device MonitoringCollection of critical information from configured field devices (Simatic and Modbus)
Connection StatusRetrieval of connection status and additional device data
Local StorageStorage in InfluxDB for local visualization and analysis
Pre-installed DashboardsInsights: System, Insights: Field Devices (new), Insights: Logs (new)
Cloud TransmissionTransmission to the cloud (AWS Endpoint): system metrics, field device states, crawler service data
  • System Metric Dashboard extended with information from additional partitions
  • Bug fix: occasional crash of data recording during connection interruptions (0 measurement points) resolved
GroupComponentVersion
SourceSimatic3.4.3
SourceModbus3.2.3
CoreSourceConfig1.0.0
GatewayEndpoint AWS1.1.0
GatewayDispatcher Insights1.9.0

The update bundle supports a migration from version 2.6.1 to 2.7.


2022-05-31

AreaDescription
Simatic ConnectorConfigured measurement variables that no longer exist on the PLC no longer cause a crash
Simatic ConnectorFetching the structure (symbolic) no longer affects data recording; frequent errors during structure discovery should also no longer occur
Grafana ConnectorStructures are fetched initially and on IPCC events and cached in RAM; requests are therefore always served from the cache (performance optimization)
System MetricsSystem metrics function for Docker containers restored

The update bundle supports a migration from version 2.6 to 2.6.1.


2022-04-26

With version 2.6, the Gateway is split into three independent services: Manager, Dispatcher, and Endpoint.

FeatureDescription
Transmission ControlStopping data transmission keeps the connection active; transmission can be stopped per Dispatcher
Connection ConfigurationConnection data and credentials can be configured via the Web UI
Connection StatusThe connection status to the Endpoint is displayed in the Web UI
Measurement Variable ManagementAlready configured measurement variables can be selected, adjusted, or removed for transmission via the Gateway (selection via Variable Browser)
FeatureDescription
Event DetectionEvent detection now works correctly (buffer adjustment in Telegraf)
GroupComponentVersion
Web UIAdvanced UI3.10.18
Web UIWeb API1.0.12.5
GatewayManager1.0.0 (new)
GatewayDispatcher MX1.0.0 (new)
GatewayEndpoint AWS1.0.0 (new)
CoreTelegraf1.20.4

The update bundle supports a migration from version 2.5 to 2.6.


2022-03-11

FeatureDescription
Health OverviewAn overview of the health status of system and core services is displayed under “Settings”
Usage LockThe UI blocks operation as long as not all system and core services are available (e.g. after a restart)
FeatureDescription
Revised UIWizard-guided setup of calculations; variable selection is done via the Variable Browser
FeatureDescription
Create Measurement VariablesMeasurement variables can be created manually by entering all required parameters
Delete Measurement VariablesIndividual or multiple measurement variables can be deleted
FeatureDescription
Selective ImportIndividual variables from a Simatic S7 (symbolic addressing) can be selectively added to existing measurement variables
HighlightingAlready imported variables and variables that no longer exist are visually highlighted
Structure PreservationExisting structures are not deleted during import
  • Angular framework updated to version 13
  • Various bug fixes: network settings, loading animations, Firefox layout, translation errors
GroupComponentVersion
Web UIAdvanced UI3.9.33

No separate download paths are stored for this version.


2022-02-21

[!WARNING] Host Updater must be updated before installation The update package from version 2.4.1 overwrote the manually updated Host Updater. Before installing this package, the Host Updater must therefore be manually updated again.

AreaDescription
Modbus & SimaticFixed an error when advancing the crawler’s system clock
SimaticMeasurement variables with the same address are now only fetched once from the PLC; the value is written to all corresponding measurement variables
GroupComponentVersion
SourceModbus3.0.11.1
SourceSimatic3.2.0

2022-01-21

[!WARNING] Host Updater is overwritten by this update The update package overwrites the manually updated Host Updater. Before installing the next update package (version 2.4.2), the Host Updater must therefore be manually updated again.

FeatureDescription
DNS ConfigurationUp to 5 DNS entries can be configured
Multiple AdaptersAll available network adapters (all eth adapters) can be configured
Hot-ApplyNetwork changes can be applied without a restart
FeatureDescription
Time SettingDate, time, and time zone can be changed without resetting to factory defaults
NTP ConfigurationNTP address and activation state are configurable
GroupComponentVersion
Web UIAdvanced UI3.7.83

2021-09-20

FeatureDescription
Automated OrchestrationConnectors are managed automatically — no manual creation of containers required
Connection StatusConnection status is determined via Docker container health checks
Metric & AlignmentConfiguration of measurement method and time alignment directly in the UI (per device and per measurement variable)
FeatureDescription
Updater (Beta)New Updater service for more convenient software updates
FeatureDescription
New Basic UISupplementary end-user UI alongside the Advanced UI
Included FeaturesDigiDoc, Dashboards, RedProcessor
GroupComponentVersion
Web UIAdvanced UI3.7.17
Web UIBasic UI1.0.7 (new)
Web UIWeb API1.0.9.6
SourceSimatic3.0.7
SourceModbus3.0.10
CoreSource-Config0.1.10
CoreStructService1.10.9
CoreDeviceConfigMgr1.0.4
CoreDBMgr1.0.2
APPDigiDoc0.1.4

2021-05-11

FeatureDescription
Menu NavigationRedProcessor is available as a menu item in the main menu; opens in a new tab
AreaDescription
DigiDocUploading new structures can now also be done directly in the UI (previously only possible via Swagger)
DigiDocThe DigiDoc database now starts automatically on system startup
GroupComponentVersion
Web UIWeb Frontend3.6.31
APPRedProcessor0.1.0.0 (new)

FeatureDescription
DocumentationNew “Documentation” menu item in the main menu
File ExplorerFiles can be browsed and downloaded

[!NOTE] Known Issue: In this version, uploading new structures is only possible via Swagger (http://<IP-CRAWLER>:8028/swagger). A fix will be included in version 2.3.4.


AreaDescription
Measurement ProcessingInvalid measurement values (NaN, INF) no longer cause data loss for other measurement values
GroupComponentVersion
SourceModbus1.0.12.0
SourceSimatic2.5.7.0
SourceOPC UA1.0.5.0

FeatureDescription
IntegrationDataProcessor is integrated into the system and accessible from the main menu
AreaDescription
KapacitorFixed incorrect addressing of the Kapacitor (introduced after the migration to Docker-Compose)

[!CAUTION] Not recommended — Known Issues This version contains a bug. It is recommended to update directly to version 2.3.1.


FeatureDescription
Docker-ComposeEntire service infrastructure migrated to Docker-Compose
MQTT-LoggerMQTT-Logger introduced as a replacement for the MessageCenter; integrated into all container services

No separate download paths are stored for this version.


FeatureDescription
SSL SupportGateway now supports SSL-secured connections to the cloud
Connection RecoveryImproved behavior when the connection to the cloud is lost

No separate download paths are stored for this version.


FeatureDescription
Metadata SeparationSeparation of measurement metadata storage: UUIDs as tags in InfluxDB, metadata in relational database
IPCCInternal event and command system for propagating changes to device and measurement structures
FeatureDescription
Modernized UIRevised and extended user interface
Variable BrowserNew Variable Browser for an overview and management of measurement variables
FeatureDescription
New GatewayNew Gateway with support for various customers

No separate download paths are stored for this version.